Leave Your Message
Eccentric Butterfly valves Mounted with Electric Actuator
News

Eccentric Butterfly valves Mounted with Electric Actuator

2026-05-14

Important Notes for Mounting AUMA Electric Actuator with DEYE Bare Stem Butterfly Valve

  1. Flange Standard: Our bare stem butterfly valve uses ISO 5211 (F05/F07/F10). AUMA mounting flange must match exactly; spigot is loose fit, no forcing.
  2. Stem & Drive: Valve stem diameter, square/flat size and key waymust 100% match AUMA output sleeve. Our valve is bare stem; AUMA uses Type B drive (ISO 5210) with bore/keyway—verify carefully.
  3. Torque Margin: AUMA output torque must be 20%–30% higherthan valve operating torque.
  4. Alignment & Bolting: Keep perfect concentricity; clean flange faces, lightly grease stem; tighten bolts crosswise evenlyper AUMA torque specs.
  5. 90° Stroke: Valve is 90° quarter-turn. Set AUMA mechanical/electrical limits exactly to 0° (closed) / 90° (open); no over-travel.
  6. Direction Check: Jog to confirm open/close direction matches valve movement.
  7. Electrical & Mounting: Verify voltage/control signal; ensure proper earthing and cable sealing; vertical mounting preferred, inverted not allowed.high performance butterfly valves with bare shaft.jpg

    DEYE VALVES also supply complete valves with actuators.

    DEYE VALVES worked with reliable China supplier of electric actuator, procurement the motor actuator, assemble the elec.actuator to provide the complete valve to clients. All valves are fully per-commissioned with a two-year warranty. 

    Important Notes for Electric Actuator Installation on Valves

    1. Selection & Matching

    1. The output torque of the electric actuator must be higher than the actual operating torque of the valve, with a 20%–30% safety margin.
    2. Valve stem diameter, key-wayand flat size shall match the actuator output shaft strictly.
    3. For hazardous area (Zone 1/2, IIC T6 etc.), explosion-proof typeis mandatory with protection grade not lower than IP65.
    4. Confirm power supply voltage (AC220V/380V) and control mode (on-off / modulating 4-20mA) to match site control system.

    2. Mechanical Installation

    1. Install vertically as preferred; if horizontally mounted, add firm support. Inverted installation is not allowed.
    2. Keep perfect alignment between valve stem and actuator output shaft; fasten flange bolts diagonally and evenly.
    3. Set mechanical limit and electrical limit in advance to avoid over-travel damage to valve seal and stem.
    4. Cable gland facing downward; ensure tight sealing for waterproof, rainproof and anti-corrosion protection.valves+modulating  elec. actuator.jpg

    3. Electrical Wiring & Commissioning

    1. Reliable grounding is required; wire power and control cables strictly according to wiring diagram.
    2. Jog test to confirm open/close directionis consistent with valve actual movement.
    3. Set torque protection properly to stop automatically in case of jamming.
    4. Test local / remote control, open / close position feedback signal completely.

    4. Environment & Warranty

    1. Keep away from direct sunlight, high temperature, water immersion and strong corrosive atmosphere.
    2. Ensure manual / electric clutch operates flexibly for emergency manual operation.
    3. Run full open-close cycle 3–5 times without abnormal noise, stuck action or leakage before acceptance.
    4. Two-year warranty is valid only under standard installation, wiring and commissioning; unauthorized modification and overloading are not covered by warranty.valves+elec. actuator on off.jpg